North and east Shropshire are dry by the standards of western England. Shawbury, on the plain, averages about 680 mm of rain a year, little more than half the UK average. Yet every winter the same calls come in: toilets slow to flush, tanks brimming, grey water lying on lawns. The reason is what happens to that rain once it lands.
Why Shropshire tanks struggle in winter
Clay that doesn't let go
Much of the north Shropshire plain, from Oswestry and Ellesmere across to Wem, Prees and Market Drayton, sits on glacial boulder clay. Clay takes water in slowly and lets it out slowly. Once autumn rain has wetted it through, the top of the soil can stay saturated from November until March, with little evaporation to dry it out.
A drainage field in that ground has nowhere to send its effluent. The trenches fill, the water level in the tank rises to the outlet, and from there it backs up the pipes towards the house. Nothing has broken. The ground has simply stopped taking water for a few months.
Rising groundwater
Shropshire Council's 2018 strategic flood risk assessment puts most of the south of the county in the lowest band for groundwater flooding, and parts of the north in higher ones. On the plain, pockets of sand and gravel over the clay can fill with water in a wet winter. A high water table can reach the base of a drainage field and stop it working, and it can seep into an old brick or concrete tank through cracks and joints, filling it with clean water that pushes sewage out ahead of it.
River floods
The Severn floods at Shrewsbury, Ironbridge and Bridgnorth's Low Town, and the Vyrnwy spreads over the meadows around Melverley on the Welsh border. The Teme and Corve rise at Ludlow, and the Clun and Onny flood their valley floors. Properties on the flood plain can have tanks and fields underwater for days. Floodwater gets into the tank through the lid and the vent, and once the water drops the tank is often full of silt and floodwater as well as sewage.
Water that shouldn't be there
Old farmhouses and cottages often have rainwater from roofs, gutters or a paved drive piped into the same drain as the sewage. In a dry spell that goes unnoticed. In winter it can double the flow through the tank, washing solids into the field. Rainwater should go to a separate soakaway or ditch, never to a septic tank.
During a wet spell
- Cut the water going in. Spread out washing, skip the bath, run the dishwasher full or not at all. Every litre saved is a litre the field doesn't have to handle.
- Check for rainwater connections. Lift the inspection chamber near the house during heavy rain. If clean water is pouring in, find where it's coming from.
- Think twice before emptying. An empty tank sitting in waterlogged ground can be lifted by the water around it. Plastic tanks and treatment plants are most at risk, and old tanks can crack. If emptying can't wait because sewage is backing up into the house, say so when you book so that the tank can be handled with care. For budgeting, a Shropshire empty is typically £180–£300 a visit, though that figure isn't a quote.
- Keep off the field. Walking or driving over saturated trenches compacts the soil and makes the problem worse.
- If sewage comes into the house, stop using water and see the emergency page.
After a flood
If floodwater has covered the tank or plant:
- Wait for the water to go down before anyone opens the tank.
- Have the tank emptied once the ground has started to drain. Silt and floodwater take up space the sewage needs.
- Check the lid, vent and inlet for damage and blockages.
- For a treatment plant, keep the power off until the control panel and blower have been checked. Electrics that have been underwater shouldn't be switched back on without inspection. The plant may need reseeding with bacteria and a service visit to restart. See sewage treatment plant servicing.
- Watch the drainage field for a few weeks. Flooding can wash silt into the trenches, and a field that floods often may never fully recover.
Is it seasonal or has the field failed?
A field that struggles from December to February and works fine the rest of the year is coping with the clay, if only just. A field that ponds in summer, or keeps ponding long after the ground has dried, has probably failed. The drainage field failure guide explains how to tell, and what replacement involves.
Making the system cope better
Some fixes are simple; others mean rebuilding.
- Separate the rainwater. Taking gutters and drive drains off the foul system is often the cheapest improvement.
- Cut off water from above. On sloping sites in the hills, a gravel cut-off drain uphill of the field can intercept water running down the slope before it reaches the trenches.
- Repair or replace a leaking tank. Stopping groundwater getting in keeps the tank doing its job. Typical repairs cost £300–£1,500.
- Rebuild the field. A larger field, or a raised mound built above the winter water table, can work where a standard field doesn't. A replacement drainage field typically costs £3,000–£8,000.
- Switch to a treatment plant to a ditch. Where the clay will never take effluent in winter, a treatment plant discharging to a ditch or stream is often the long-term answer. Septic tanks can't discharge to surface water; a plant can, within the rules. In the Melverley, Rea and Strine drainage districts, a new outfall into a board drain also needs the board's consent; see the drainage boards page.
Whatever the option, a winter trial pit shows how high the water really gets, which is the number a good design is built around.
Questions
Why does my septic tank overflow every winter but not in summer?
Usually because the drainage field is in clay or high groundwater. In summer the soil has room to take effluent; in a wet Shropshire winter it's already full of water, so the effluent backs up into the tank. Emptying gives short-term relief, but the lasting fix is in the field, not the tank.
Can a septic tank float out of the ground?
Yes, if it's emptied while the surrounding ground is waterlogged. The water pressure around an empty tank, especially a lighter plastic tank or treatment plant, can push it upwards and break the pipe joints. This is why emptying in saturated ground is done with care, and sometimes delayed.
My tank was under floodwater from the Severn. Is it safe to use?
Use as little water as possible until the floodwater has gone down, then have the tank emptied and checked. Look for damage to the lid and pipes, and if you have a treatment plant, keep the power off until the electrics have been inspected.
Does home insurance cover septic tank flood damage?
It depends on the policy. Some buildings policies treat a septic tank as part of the property and cover flood damage to it; others exclude underground services or gradual wear. Check the wording and keep records of when the tank was last emptied and serviced.