Every septic tank and small sewage treatment plant in England either meets the Environment Agency's general binding rules or needs an environmental permit. There is no third option. For the great majority of Shropshire homes the rules are easy to meet: a sound tank, a working drainage field, and regular emptying. The trouble spots in this county are predictable, though. Clay on the northern plain, springs feeding hill farms, the sandstone aquifer in the east, and protected rivers and wetlands all change how the rules apply.
GOV.UK publishes two sets: one for discharges to the ground (updated 23 July 2026) and one for discharges to surface water. Its overview for owners ties the two together.
Who has to comply
The duty falls on the operator. That's usually the owner of the property the system serves. Shared tanks are common in Shropshire: think of a Corvedale or Clun Forest farm whose stone barns became three or four separate homes, all still draining to the one tank by the old fold. In that case every owner is an operator, jointly. A lease or other agreement can also make a tenant the operator. If you're on the public sewer, none of this applies.
The rules cover England only. Over the border in Powys or Wrexham, Natural Resources Wales runs a different system; see the Welsh border.
Three generations of rules
What you must meet depends on when your discharge began:
| Discharge started | Rules that apply |
|---|---|
| Before 1 January 2015 | The rules for all discharges |
| 1 January 2015 to 1 October 2023 | Those, plus the 2015 additions |
| On or after 2 October 2023 | Those, plus the 2023 additions |
An older discharge is treated as new if it switches between ground and surface water, moves more than 10 metres, or grows beyond the volume limit. Replacing a tank on the same spot doesn't do that by itself, but relocating the drainage field often does. The tests are on GOV.UK's new discharges page.
Volume
- To ground: no more than 2 m³ (2,000 litres) a day.
- To surface water: no more than 5 m³ (5,000 litres) a day.
A single household is nowhere near either. The limits start to matter on farms with several lets, wedding barns and small sites. GOV.UK points to Defra's calculator for homes and British Water's Flows and Loads guidance for holiday and commercial use.
Conditions for every discharge
- Domestic sewage only: toilets, bathrooms, showers and kitchens.
- It must not pollute groundwater or surface water.
- Treatment, then a drainage field. A septic tank must never empty straight into a watercourse.
- No discharge into a well or borehole, and no rainwater-style soakaway built after December 2007.
- Raised mounds count too, provided they're built to BS 6297:2007 and sit outside a floodplain. Since July 2026 GOV.UK also accepts ground engineered to reduce the percolation rate, for sites that drain too fast, provided it reaches a percolation value of at least 15. It doesn't help on the slow clay of the north Shropshire plain.
- Source Protection Zone 1 (except SPZ1c) needs a permit, and so does anything within 50 metres of a private water supply used for drinking. Both catch people here. The east of the county sits on Shropshire's Permo-Triassic sandstone aquifer, and some hill farms on the Long Mynd and in Corvedale still draw from a spring or well. Check the zones on the Environment Agency's map before planning a field.
- British Standards apply by date. The current ones are BS EN 12566, covering tanks and plants, and BS 6297:2007, covering drainage fields; an older system is judged against whatever version applied on the day it went in. Anything installed before 1983 is exempt from the standard, though not from the other rules.
- The system must be big enough for its load and installed and run as the maker specifies.
The 2015 additions
- Sewer distance. A single home can't use the rules when the public foul sewer comes within 30 metres of any boundary of the property. For a group of houses, multiply 30 metres by the number of homes.
- Planning and building regulations. A new tank or plant needs building regulations approval, and may need planning permission. In Shropshire that's Shropshire Council building control, or Telford & Wrekin for the Telford fringe.
- Protected sites, to ground. Not in ancient woodland, or within 50 metres of an SAC, SPA, Ramsar site or biological SSSI.
- Protected sites, to water. Not within 500 metres of an SSSI, SAC, SPA, Ramsar site or a freshwater pearl mussel population, among others. The outlet must also go to water that flows all year, not to a ditch that dries out in summer or a sealed pond.
In Shropshire those distances fall on the River Clun SAC and the Midland Meres and Mosses Ramsar sites. See the River Clun and the meres and mosses.
The 2023 additions
For discharges that started on or after 2 October 2023:
- A new system can't share an outlet with another if the combined flow would exceed the limit.
- It can't be within 50 metres of another system already running under the rules.
The second point catches farm clusters. Two neighbouring barn conversions can't each put in a plant on the same corner of a field and both rely on the rules. One shared, properly sized plant, or a permit, may be the answer.
Looking after the system
- Maintenance. Follow the manufacturer's instructions, and have the work done by someone competent. Repair or replace anything not in good working order: leaks, cracked pipes, blockages, wet ground at the outlet, smells, or a failed pump.
- Emptying. Desludge before the sludge reaches capacity. GOV.UK's guide is at least once a year, or as the manufacturer says. Typical Shropshire emptying runs £180–£300 a visit; see septic tank emptying costs.
- Waste carrier. The firm removing the sludge has to hold waste carrier registration. Ask to see the certificate.
- Keep the paperwork. Emptying receipts and service sheets are what a buyer's solicitor will ask for.
Selling, and stopping
When you sell, you must give the new operator a written description of the system: what it is, where the parts and outlet are, any changes, and how it should be maintained. See selling a house with a septic tank. When you stop using a system for good, you must remove anything that could pollute, such as the remaining sludge; see decommissioning.
When a permit is needed
Only when you can't meet the rules. The Environment Agency issues standard rules permits for lower-risk cases and bespoke permits for the rest, and generally only where a sewer connection isn't reasonable. The find out if you need a permit page sets out the route. For a quick read on your own position, try the do I need to upgrade? checker. To have an existing tank or plant checked against each of these rules on the ground, book a septic tank compliance survey.
Questions
Does the Environment Agency keep a list of septic tanks I need to join?
Not in England. Registration of exempt systems ended on 1 January 2015, when the general binding rules took over. If your system meets the rules, there's nothing to apply for. In Wales it's different: Natural Resources Wales still expects systems to be registered.
Is a tank installed before 1983 automatically compliant?
No. It doesn't have to meet a British Standard, but it must still drain to ground, avoid pollution, be maintained and be emptied by a registered waste carrier.
What changed in the July 2026 update, and does it help on clay?
Since 23 July 2026 the rules also cover discharges to ground "engineered to reduce the percolation rate", so a site that drains too fast can be made to work. The engineered ground has to reach a percolation value (Vp) of at least 15, sit outside a floodplain and follow BS 6297:2007. It's an option on free-draining ground, such as the sandstone of east Shropshire or the sand and gravel pockets on the northern plain. It isn't a fix for heavy clay.
Can two new systems go side by side on one farm?
Not under the general binding rules, if both started after 2 October 2023 and are within 50 metres of each other. A shared plant or a permit is usually needed.
